Power
Transformer
Technical Specification
- Range : 5 MVA to 15 MVA
- Voltage Class : 11 KV, 22 KV, 33 KV
- Cooling : ONAN /AF
- Taping : OFF Load Tap Changer/On load Tap changer.
Description
A reliable power supply presupposes a sufficiently large supply system with high- performance transformers. The high quality standards set by us are appreciated throughout the world and these are applied to development, manufacture, installation and commissioning of power transformers for power stations, transformers stations and auxiliary plants for generating stations, special transformers for industry and power plants.
Distribution
Transformer
Technical Specification
- Range : 100 KVA to 5000 KVA
- Voltage Class : 11 KV, 22 KV, 33 KV
- Cooling : ONAN
- Taping : OFF Load Tap Changer/On load Tap changer.
Description
The Distribution Transformer offered by us is used to control the power distribution to individual loads and offer security for load cables. These are offered with in different KVA ranging from 100 KVA to 5000 KVA as per the requirement of our clients.
Cast Resin Dry Type
Transformer
Technical Specification
- Range : Up to 5 MVA
- Voltage Class : 11 KV, 22 KV, 33 KV
- Protection : Up to IP 55
- Cooling : AN, AF
- Winding Material : Copper
- Insulation Level : 'F' & 'H' Type
- Taping :On load Gears.
Description
The CAST Dry Type Transformers with ON LOAD Tap changer manufactured by us offered up to 5000 KVA .These are Dry Type Transformers offered with On-load Tap changer that enables the to handle the high and fluctuating load with ease. Further, we have been appreciated for its features such as quality, durability and temperature tolerance, Very high INSULATION up to 8 paper covering of NOMEX paper is used.
Dry Type
Resin Dipped
Transformer
Technical Specification
- Range : Up to 5 MVA
- Voltage Class : 11 KV, 22 KV, 33 KV
- Protection : Up to IP 55
- Cooling : AN, AF
- Winding Material :Aluminum or Copper
Advantage
- Fire Resistance
- Space Saving
- Low Loasses
- Maintainence Free
- Transformer easy to install
- Self Extingguishing
- Possible to install near load point
- Reduce Noise Level
- High Over Load capacity
- Short Circuit Resistance
- Perfect Isolation to High Voltage
Furnace
Transformer
Technical Specification
- Range : Up to 15 MVA
- Voltage Class : 11 KV, 22 KV, 33 KV On LV side 80V to 240V
- Protection : Up to 15000Amps
- Cooling :AF, ONAN
- Winding Material : Copper , F class
Advantage
Our Furnace Transformer are designed to take load up to 15000Amps. Special High Insulation including fibre glass is used
Dry Type
Transformer With On-Load Tap Changer
Technical Specification
- Range : Up to 5 MVA
- Voltage Class : 11 KV, 22 KV, 33 KV
- Protection : IPOO / IP55
- Cooling : AN, AF
- Tapping: On Load Tap Changer
- Winding Material : Copper
Advantage
The CAST Dry Type Transformers with ON LOAD Tap changer manufactured by us offered up to 5000 KVA .These are Dry Type Transformers offered with On-load Tap changer that enables the to handle the high and fluctuating load with ease. Further, we have been appreciated for its features such as quality, durability and temperature tolerance, Very high INSULATION up to 8 paper covering of NOMEX paper is used.
Solar Invertor Duty Transformers
Technical Specification
- Range : Up to 15 MVA
- Voltage Class : 11 KV, 22 KV, 33 KV
- Cooling : ONAN, AF
- Winding Material : Copper, A Class Insulation
Advantage
Electric power is generated by converting solar energy to d.c by using photovoltaic (PV) cells. The DC generated is converted to a.c by inverters and the a.c is connected to the power grid by a step up transformer. The international standard applicable for the transformers for DPV generation is IEEE C57.159 2016 “IEEE Guide on transformers for application in distributed photovoltaic (DPV) power generation system”. At present there are limitations on the power rating and voltage level of the inverter system and therefore one or more inverters are connected to an equal number of secondaries of the step up transformers. Though the most common configuration is 2 to 3 secondaries, at present transformer with 6 secondaries are also manufactured. Inverter manufacturers are now developing inverters with higher power and voltage ratings and this would increase the transformer MVA ratings in future and reduce the number of secondary windings required.
Our Salient Features
Why to choose us?
- Manufacturing of all kind of power and distribution Transformer up to 10MVA, at 66KV class.
- Manufacturing of all kind of custom built transformer like Cast Resin, Dry Type, Furnace, Isolation, Rectifier, Earthing, Mining, Auto, Converter duty , Traction Transformer, Regulator and AVR .
- On site oil filtration through vacuum plant of John Fowler Make at your site.
- Repairing and conversion of any old transformer of any ratio or capacity with 12 month guarantee.
- Transformer available at ex-stock and on RENT.
- Retro-fitting of transformers with zero leakage.
- Overhauling of any make Transformer.